b) RANGE - Manual Measurement Range Selection
TheRANGEfunctionpermitsmanualsettingofaspecicmeasurementrange.Itispossiblethattheautomaticmeas-
urement range setting will already select the next-higher measurement range or switch between ranges if the range is
problematic. To suppress this, the measurement range can be set manually in some measuring functions.
The manual measuring range setting works in all measuring functions, except: Motor, mV, continuity test and diode
test.
Pushingthe“RANGE”buttonwillcausethe“AUTO”symboltogooutandthedevicetoswitchtomanualmode.
Eachpushofthe“RANGE”buttonswitchesthemeasurementrange;attheend,itwillstartwiththelowestmeasure-
ment range again. The respective measurement range is indicated by the position of the decimal point.
Toswitchoffthisfunction,keepthe“RANGE”buttonpressedforapprox.2s.The“AUTO”symbolappearsandthe
automatic measurement range selection is active again. Switching the measuring function deactivates this function
as well.
c) MAX MIN Function
This function permits saving and display of maximum or minimum values during
ameasuringseries.Pressthe“MAXMIN”buttontoactivatethismeasuring
function. Auto-range is deactivated.
With the active function, the minimum and maximum value of the current
measuring series is saved at the same time.
The max. and min. display is shown in the small subdisplay and can be
switched with every push of a button (MAX MIN).
The values are deleted after a measuring function change or when switching
off the device.
Todeactivatethefunction,keepthe“MAXMIN”buttonpushedforapprox.2
seconds.Thedisplay“MAX”or“MIN”disappearsand“AUTO”appearsagain.
This additional function cannot be activated in the measuring
function "LPF", "Motor", "V AC+DC", continuity, diode test
and "Hz”.
d) REL Function
The REL function allows a reference value measurement to avoid possible scatter displays or line loss as it occurs,
e.g., during impedance measurements. For this purpose, the current indicated value is set to zero. A new reference
value is set. Auto-range is deactivated.
Pressthe“REL”buttontoactivatethismeasuringfunction.Thedisplayindicates“Δ”.
Inordertoswitchoffthisfunction,pushthe“REL”buttonagainorchangethemeasurementfunction.
This additional function cannot be activated in the measuring function “Motor” and “Hz”.