Instructions

58
e) PEAK function, peak value recording
The PEAK function permits quick recording of peak values (Peak) during a
measuringseriesinthealternatingvoltagerange.Thepeakvalues“P-MAX”
and“P-MIN”arerecordedatthesametimeinatimewindowof250µs.
Pressthe“PEAK”buttontoactivatethismeasuringfunction.Auto-rangeis
deactivated.
The P-MAX and P-MIN-display is shown in the small subdisplay and can be
switched with every push of a button (PEAK).
The values are deleted after a measuring function change or when switching
off the device.
Todeactivatethefunction,keepthe“PEAK”buttonpushedforapprox.2sec-
onds.Thedisplay“P-MAX”or“P-MIN”disappearsand“AUTO”appearsagain.
f) HOLD Function
The Hold function keeps the currently indicated measured value in the displays to allow you to read or record it easily.
If you test live wires, make sure that this function is deactivated before the measurement starts.
Otherwise, the measurement will be incorrect!
This additional function cannot be activated in the measuring function “Motor”
ToswitchontheHoldfunction,pushthe“HOLD”button;asignalsoundconrmsthiscommandand“H”appearson
the display.
InordertoswitchofftheHoldfunction,pushthe“HOLD”buttonagainorchangethemeasurementfunction.
g) Display Illumination
The multimeter automatically recognises the brightness in the environment via a light sensor and switches on dis-
playlightingautomaticallywhentheDMMison.Thisautomaticfunctionisdisplayedbythesymbol“BL”.Itcanbe
deactivated via the lighting button and remains deactivated until switched off via the dial switch. This automatic
function is activated again at the next activation.
h) LED Lamp
A white LED lamp (K) is integrated at the rear of the device. The lamp is switched on and off via the button with the
torch icon. Every push of a button will switch the lamp on or off again.
The lamp remains on until switched off manually via the button, until the meter is switched off via the dial switch (OFF)
or the device is deactivated automatically after approx. 15 minutes.