Instructions
52
e) Hz% Function, Frequency Measurement (electrical)
The voltage and current measurement ranges are occupied with subfunctions for frequency measurement. These 
measuring functions require a signal level of >200 mVrms and have a bandwidth of up to 400 Hz. They are therefore 
suitable for mains voltage.
Tomeasurethefrequencyofthecurrentorvoltagesignal,pushthebutton“Hz%”.Thedisplayshowsthefrequency
inHz.Toswitchthedisplay,pushthebutton“Hz%”again.
Pulse Ratio “Hz%” Function
Ifyouwouldliketodisplaytheratioofthepositivetothenegativehalfwaveinpercent,pushthebutton“Hz%”twice.
Thedisplayshowstheratioofthepositivehalf-waveinpercent.Toswitchthedisplay,pushthebutton“Hz%”again.
f)  HOLD Function
The Hold function keeps the currently indicated measured value in the displays to allow you to read or record it easily.
  If you test live wires, make sure that this function is deactivated before the measurement starts. 
Otherwise, the measurement will be incorrect!
ToswitchontheHoldfunction,pushthe“HOLD”button;asignalsoundconrmsthiscommandand“H”appearson
the display. The bar chart remains active and displays the voltage curve.
InordertoswitchofftheHoldfunction,pushthe“HOLD”buttonagainorchangethemeasurementfunction.
g) Display Illumination 
The multimeter automatically recognises the brightness in the environment via a light sensor and switches on display 
lightingautomaticallywhentheDMMison.Thisautomaticfunctionisdisplayedbythesymbol“BL”.Itcanbedeacti-
vated via the lighting button
and remains deactivated until switched off via the dial switch. This automatic function 
is activated again at the next activation.
h) LED Lamp 
A white LED lamp (K) is integrated at the rear of the device. The lamp is switched on and off via the button with the 
torch icon. Every push of a button will switch the lamp on or off again.
The lamp remains on until switched off manually via the button, until the meter is switched off via the dial switch (OFF) 
or the device is deactivated automatically after approx. 15 minutes.
i)  Automatic Power-Off
The DMM turns off automatically after approx. 15 minutes if no button or rotary switch is operated. This function 
protects the battery, saves battery power and extends the operating time. The active function is displayed with the 
symbol “ “ in the display.
To reactivate the DMM after automatic deactivation:, use the dial switch or push any button (apart from the two lighting 
buttons).
Automatic deactivation can be deactivate manually.
Switchoffthemeter(OFF).Keepthebutton“SELECT”depressedandSwitchontheDMMattherotarycontrol.The
“ “ symbol is not visible. Automatic switching off remains inactive until the meter is turned off via the rotary control.