Instructions
50
k) Frequency Measurement (electronic)
The DMM can be used to measure and indicate signal voltage frequencies up to 10 MHz. The maximum input range 
is 30 Vrms. This measuring function is not suitable for mains voltage measurements. Please observe the input values 
in the technical data.
 Formainsvoltagemeasurements,usetheadditionalfunctions“Hz”and“%”inthecorrespondingvoltage
and current measurement ranges.
Proceed as follows to measure frequencies: 
 - Turnthe DMMonandselect measuring function“Hz”.
Thedisplayindicates“Hz”.
 - Plug the red measuring line into the Hz measuring jack 
(E) and the black measuring line into the COM measur-
ing jack (D).
 - Connect the two measuring prods to the object to be 
measured in parallel (signal generator, circuit, etc.).
 - The frequency and corresponding unit are displayed.
 - Remove the measuring lines from the object to be meas-
ured after completion of the measurement and switch off 
the DMM.
Proceed as follows to measure the pulse ratio of the positive half-wave in %: 
 - SwitchontheDMMandselectmeasuringrange“Hz”.Thedisplayindicates
“Hz”.Pushthebutton“Hz%”.Thedisplayindicates“%”.
 - Plug the red measuring line into the Hz measuring jack (E) and the black 
measuring line into the COM measuring jack (D).
 - Connect the two measuring prods to the object to be measured in parallel 
(signal generator, circuit, etc.).
 - The pulse duration of the positive half wave is displayed as a percentage. 
50% is displayed for a symmetrical signal.
 - Remove the measuring lines from the object to be measured after comple-
tion of the measurement and switch off the DMM.