a) Current clamp
1 Clamp
2 Setting wheel
3 Light button
4 LCD display
5 Battery compartment (back)
6 Hole for a strap
7 MAXH button
8 HOLD button
9 Opening lever
b) LCD display
Symbols
No. Symbol Control display/display
A A Control display - current
B -- Measurement value
C MAXH Control display - maximum value
D
Control display - hold
E
Control display - battery
F AC Control display - alternating current
Resolution
Measurement range Resolution Accuracy
2.000 A~ 1 mA ± (4 % + 30)
20.00 A~ 10 mA ± (3 % + 10)
200.0 A~ 100 mA ± (2.5 % + 5)
Speciedaccuracy±(%ofthereading+displayerrorsincounts).Theaccuracyismaintained