4. First Aid Measures
The product contains corrosive electrolyte, in case of electrolyte leakage from the battery, action described below are required.
Skin contact:
Wash this contacted areas off immediately with plenty of water. If appropriate procedures are not taken, this may cause sores
on the skin.
Eye contact:
Flush the eyes with plenty of clean water without rubbing. Take a medical treatment. If appropriate procedures are not taken,
this may cause an eye irritation.
Inhalation:
Remove to fresh air immediately. Take a medical treatment.
Extinguishing method:
Since vapor, generated from burning batteries may make eyes, nose and throat irritate, be sure to extinguish the fire on the
windward side. Wear the respiratory protection equipment in some cases.
Fire extinguishing agent:
Dry chemical, alcohol-resistant form, carbon dioxide and plenty of water area effective.
5. Fire-fighting Measures
Flash Point: NA
Lower Explosive Limit: NA
Upper Explosive Limit: NA
Extinguishing Media:
Water, Foam, Dry. Any class of extinguishing medium may be used on the batteries or their packing material.
Special Fire Fighting Procedures:
Exposure to temperatures of above 100°C can cause venting of the liquid electrolyte. Internal shorting could also cause
venting of the electrolyte. There is potential for exposure to iron, nickel, cobalt, rare earth metals, manganese, and aluminum
fumes during fire; use self-contained breathing apparatus.
6. Accidental Release Measures
Stepts to be taken in case material is released or spilled:
The preferred respinse is to leave the area and allow the batteries to cool and the vapours to dissipate. Avoid skin and eye
contact or inhalation of vapours. Collect all released material in a plastic lined metal container and remove spilled liquid with
absorbent. Doing this, protect your skin and eyes with gloves and protection glasses.