User manual
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE. *1433327_28_29_V2_0616_02_VTP_m_en
Technical Data
TOPS-3205 TOPS-3363 TOPS-3602
Output voltage 1 - 20 V/DC 1 - 36 V/DC 1 - 60 V/DC
Output current 0.25 – 5 A 0.25 – 3 A 0.25 – 1.6 A
Display resolution 0.01 V / 0.001 A
Display accuracy "V"
< 5 V: ±0.05 V
≥ 5 V: ±(0,2% + 0.05 V)
Display accuracy "A"
≤ 1 A: ±0.015 A
> 1 A: ±(0,5% + 0.006 A)
Max. output power 100 W
Residual ripple (p-p) <120 mV <150 mV <180 mV
Control response at
Change of load 10~90%
70 mV
50 mA
Control response at
Mains change 10%
25 mV
20 mA
Output USB AUX 1 5 V/DC, max. 1.8 A
Output USB AUX 2 5 V/DC, max. 1.8 A
Mains fuse
5x 20 mm ne fuse
T2A/250 V time lag
Operating temperature +5 °C to +40 °C
Rel. Humidity max. 85%, non-condensing
Max. operating altitude 2000 m above sea level
Pollution degree 2
Operating voltage 100 - 240 V AC, 50/60 Hz
Power consumption max. 1.6 A (at 230 V ca. 0.83 A)
Protection class 1
Power factor (active PFC) >0.9
Degree of effectiveness ≥80.5 %
Unit' cooling system Convection
Dimensions (W x H x D) 70 x 150 x 250 (mm)
Weight 2 kg
LVD Directive 2006/95/EC EN 61010