Datasheet
TECHNICAL DATA
Display 2000 counts
Auto-Power OFF after approx. 15 minutes, a signal sounds; deactivation takes
place after another minute.
Input resistance >7.5 MΩ
Measuring type Average measurement
Operating voltage DMM: 3 V/DC (2 x AAA)
Sat-Finder 13 - 18 V/DC
Operating altitude Max. 2000 m above sea level
Degree of contamination 2
Working temperature 0°C to +40°C
Storage temperature -10°C to +50°C
Weight Approx. 308 g
Dimensions (LxWxH) 162 x 75 x 44 (mm)
Direct voltage range, overload protection 600 V
Range Accuracy Resolution
200 mV ±(0.5 % + 3) 0.1 mV
2 V
±(1 % + 3)
1 mV
20 V 10 mV
200 V 100 mV
600 V 1 V
Alternate voltage range, overload protection 600 V
Area (50 - 60 Hz) Accuracy Resolution
2 V
±(1 % + 5)
1 mV
20 V 10 mV
200 V
±(1.5 % + 10)
100 mV
600 V 1 V
Resistance range
Range Accuracy Resolution
200 Ω ±(0.8 % + 5) 0.1 Ω
2 kΩ
±(1.2 % + 3)
1 Ω
20 kΩ 10 Ω
200 kΩ 100 Ω
2 MΩ ±(2 % + 5) 1 kΩ
20 MΩ ±(5 % + 8) 10 kΩ
Acoustic Continuity tester <150 Ω
Diode test voltage 1.5 V/DC; test current: max. 1 mA
PACKAGE CONTENT
Meter // 2 x AAA batteries // Safety test leads // Operating instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE. V2_0914_02-ETS-Mkde