Instructions
25
10. Care and cleaning
Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause
damage to the housing and malfunctioning.
• Disconnect the product from the mains before each cleaning.
• The switched-mode mains power supply units are maintenance-free, apart from the need to replace fuses and
cleaning them once in a while. Use a clean, lint-free, antistatic and dry cloth to clean the device.
11. Disposal
1Product
Electronic devices are recyclable waste and must not be disposed of in the household waste. At the end of
its service life, dispose of the product in accordance with applicable regulatory guidelines.
Youthusfulllyourstatutoryobligationsandcontributetotheprotectionoftheenvironment.
12. Technical data
SPS 1525 PFC SPS 1540 PFC SPS 1560 PFC
Operating voltage 230V~/50Hz
Powerconsumption max.460VA max.782VA max.1058VA
Output3-15V/DCvoltage (variable)orxedvoltageof13.8V 1-15V/DCcontrollable
Output current 25 A 40 A 5Afront;60Arear
Residual ripple 10mVrms(rms=effective) max.40mVp-p
Control response at Change
ofmainssupply+/-10%:
Changeofload0~100%:
80mV
230mV
0.05%+3mV
0.1%+5mV
Mains fuse 3.15A/250V
(fastblowing)
5A/250V
(fastblowing)
Operating temperature +0°Cto+40°C
Rel. humidity max.85(non-condensing)
Dimensions(WxHxD) 220 x 110 x 240 mm 220 x 110 x 310 mm 220 x 110 x 360 mm
Weight approx. 2.6 kg approx. 3.5 kg approx. 5.8 kg