Instructions
23
Thevoltageontheremotecontrolconnectionmaynotexceed5V.
The connections may not be shorted.
2. Switch off the switched-mode power supply and then connect the REMOTE plug to the rear remote connection.
Screw down the external fastening ring.
Turnthevoltageoftheexternalvoltagesourcetozero.
3. SlidetherearVOLTAGEREMOTE switchto
the “ON” position.
4. Switch the switched-mode power supply on. The desired output voltage can now be set through the external volt-
agesource.Controlthecompleteadjustmentareaforcorrectfunction.
5. If this remote control function is no longer required, the switch to the “OFF” position.
3Control through a controllable resistance (poti)
The power unit can be remote-controlled by means of an external poti of 5 KOhm over the complete output voltage range.
Proceedasfollowsforconnection:
1. Connect the connecting cable of the REMOTE plug as illustrated.
- Connection 1 at one end of the resistance.
- Connection 2 at the centre sliding contact of the resistance.
- Connection 3 at the second end of the resistance.
2. Switch off the switched-mode power supply and then connect the REMOTE plug to the rear remote connection.
Screw the external fastening ring.
3. SlidetherearVOLTAGEREMOTEswitchto
the “ON” position.
4. Switch the switched-mode power supply on. The desired output voltage can now be set through the external poti.
Controlthecompleteadjustmentareaforcorrectfunction.
5. If this remote control function is no longer desired, move the switch to the “OFF” position
4Enable and disable the output
YoucanusePort7and8toremotecontroltheoutputon/off.
• OpenPort7and8ifyouwanttoenabletheoutput(default).