Instructions
37
Automatic deactivation at specic charging capacity
This safety function of the charger terminates charging automatically when a
certain capacity has been "loaded" into the battery.
However, do not set a capacity which is too low; otherwise the re-
chargeable battery cannot be fully charged and charging will be
interrupted early.
The safety function can be switched on ("ON") or off ("OFF").
Monitoring of the DC input voltage
This function monitors the voltage at the DC charger input. This is sensible
when a 12 V car lead battery is used for power supply. If the voltage drops
below the set value, charging is terminated to prevent deep discharge of the
car lead battery.
Switching the key conrmation sounds/warning sounds on/off
With the option "Key beep", conrmation beep for each push of a button is
switched on ("ON") or off ("OFF").
The function "Buzzer" switches the signal sound for various functions/warning
messages on ("ON") or off ("OFF").
Max. cell voltage when charging
The maximum cell voltage can be set depending on the set rechargeable bat-
tery type (LiPo, LiIon, LiFe, LiHV and Pb).
The charger ends charging when all cells have reached the set voltage.
LiPo: 4.00 - 4.24 V/cell (basic setting 4.20 V)
LiIon: 3.90 - 4.20 V/cell (basic setting 4.10 V)
LiFe: 3.40 - 3.65 V/cell (basic setting 3.60 V)
LiHV: 4.00 - 4.40 V/cell (basic setting 4.35 V)
Pb: 2.20 - 2.40 V/cell (basic setting 2.40 V)
Key beep ON
Buzzer ON
Capacity Cut-Off
ON 5000mAh
Input Power Low
Cut-Off 11.0V
Battery end volt
LiPo 4.20V/C
Battery end volt
LiIo 4.10V/C
Battery end volt
LiFe 3.60V/C
Battery end volt
LiHV 4.30V/C
Battery end volt
Pb 2.40V/P