Instructions
33
14. Saving/Loading Rechargeable Battery Data
The charger has 10 memory slots in which you can store often-used settings. For example, the data (cell number,
charging procedures, charging current) for 3 different LiPo ight batteries can be saved there, so that you do not have
to set them anew every time.
a) Saving Battery Data
• Select the function "Memory Save" in the main menu of the charger with the
button "BATT TYPE./STOP" or "DEC".
• Conrm the selection by pressing the "START/ENTER" button. The memory
number ashes.
• Select one of the 10 memories (0....9) with the button "INC" or "DEC".
When the memory is empty, "NULL" is displayed.
If there already are data in the memory, the display will alternate,
e.g., the rechargeable battery type, rechargeable battery program,
cell number, as well as the charging and discharging current.
• Hold the "START/ENTER" button for about one second to start the setting
mode. The rechargeable battery type is displayed rst; see example in the
gure on the right.
Briey pushing the "BATT TYPE./STOP" button will take you one step back or out of the setting mode.
• Select the rechargeable battery type (LiPo, LiIon, LiFe, LiHV, NiMH, NiCd, Pb) with the "INC" or "DEC" button, then
briey push the "START/ENTER" button.
The following display depends on the rechargeable battery type. A LiPo
rechargeable battery has been selected in the rst step in the gure on the
right (see above).
• Briey push the "START/ENTER" button to switch between the respective available setting options. The respec-
tively adjustable value ashes.
• Modify the value ashing using the "INC" and "DEC" buttons. Keep the respective button pressed for quick adjust-
ment.
• To save the settings, keep the button "START/ENTER" pressed for 3 sec-
onds. The display now shows the data of the memory and the memory slot
number ashes.
• The "INC" or "DEC" button selects another memory slot to programme it or change an existing programming.
Briey pushing the "BATT TYPE./STOP" button leaves the setting mode. The charger is in the main menu
again.
PROGRAM SELECT
Memory Save
MEMORY [0]
NULL
MEMORY LiPo [0]
BAL 3S 1.0A
BATT TYPE
LiPo Battery
LiPo BAL-CHG 3S
C= 3000mAh 3.0A
MEMORY LiPo [0]
BAL 3S 1.0A