Instructions
31
The maximum possible charging current depends on the battery type and number of cells. The maximum
charging power is 100 W for each channel.
Conrm the set charging current with the "START/ENTER" button.
• The number of the cells in the lower right of the display ashes. Set the number of the cells with the buttons "INC"
and "DEC". Keep the respective button pressed for quick adjustment.
Conrm the number of the cells by pressing the "START/ENTER" button.
• When no display is ashing anymore, start charging by keeping the "START/
ENTER" button pushed (approx. 3 seconds).
The charger now examines the connected rechargeable battery.
If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the appropriate
information is shown on the display. You can stop the warning signal by pressing the "BATT TYPE./STOP"
button. You then return to the previous conguration menu.
If no error was recognised, e.g. the display on the right will appear (alternat-
ing).
The "S:" value indicates the cell number that you have set in the menu (in
the example a 3-cell rechargeable lead battery).
The "R:" value indicates the cell number that the charger has recognised (in
the example also a 3-cell rechargeable lead battery).
If these two numbers do not match, please check the settings on the charger and the battery itself. It may
be that the lead battery has been completely discharged, or a cell may be faulty. In this case, the battery
should not be charged, as there is a risk of re and explosion!
You can return to the previous conguration menu using the "BATT TYPE./STOP" button.
• If the two numbers match, you can start the charging process by briey pushing the "START/ENTER" button.
• Charging begins. The display will show various information on the current
charging progress.
At the upper left, the rechargeable battery type and the cell number are
displayed ("Pb6" = lead battery with 6 cells); the charging current is shown
in the upper middle and the current rechargeable battery voltage at the
upper right.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in the middle the elapsed
charging time and the charged capacity in mAh are displayed to the right of this.
Various information is indicated on the display during a charge/discharge process by repeatedly pressing
the button "DEC" (see chapter 18). If you do not push any button for a few seconds, the charger will return
to the normal display.
• After completion of charging, an audio signal is emitted (if it has not been turned off).
If you wish to cancel the charging process prematurely, push the button "BATT TYPE./STOP".
BATTERY CHECK
WAIT...
Pb6 1.0A 12.3V
CHG 022:45 00690
S: 6SER R: 6SER
CANCEL(EXIT)
S: 6SER R: 6SER
CONFIRM(ENTER)