Datasheet

GENERAL SPECIFICATIONS
OPERATING VOLTAGE: 230 V/AC, 50 Hz TYPE OF BATTERY: 2 x 1.5 V button cell battery (LR44) RESOLUTION:
0.01 W (< 20 W) / 0.1 W (
20 W) MAX. CURRENT / POWER / VOLTAGE: 5 A, 1150 W, 230 V WEIGHT: 156 g
DIMENSIONS (W x H x D): 54 x 133 x 61 mm
TECHNICAL DATA
Parameter Value Accuracy*
Overvoltage category: CAT II (250 V) ---
Own consumption: < 1 W ---
Mains frequency: 40 - 70 Hz ---
Min. measurable power: 0.05 W (0.0002 A) ---
Measurement / display range
active power:
0.05 W - 2 W ± (5 % / 0.05 W)
2 W - 500 W ± 3 %
Display range kWh: 0 - 9999 kWh ± 3 %
Operating temperature: +5 ºC to +40 ºC ---
Operating air humidity: max. 90 % RH ---
Operating height: max. 2000 m ---
Fuse type: T5H250V ---
*Accuracy is given under the following conditions:
Mains frequency: 45 - 65 Hz
Room temperature: 23 ºC ± 5 ºC
Total Harmonic Distortion (THD): < 15 %
Load current: 1 A, sinusoidal, 50 – 60 Hz
PACKAGE CONTENT
Measuring instrument // 2 x button cell batteries LR44 // Operating instructions
This data sheet is published by Voltcraft®, Lindenweg 15, D-92242 Hirschau / Germany, Phone +49 180 586 582 7. The data sheet reflects the current
technical specifications at time of print. We reserve the right to change the technical or physical specifications.
© Copyright 2010 by Voltcraft®. V2_0710_02-SB