Datasheet
TECHNICAL DATA
Display LCD, 4000 Counts (digits) with bargraph
Measuring rate approx. 2 measuring operations/second
Measuring lead length approx. 80 cm each
Measuring impedance >10MΩ (V range)
Automatic Power-Off approx. 30 minutes
Voltage supply 6 x mignon batteries (AA)
Working conditions 0 - 40°C (<80%rF)
Operating altitude max. 2,000 m
Storage temperature -10°C to +60°C (<70%rF)
Earth DMM approx. 550 g
Dimensions (LxWxH) 200 x 92 x 50 (mm)
Over-voltage category CAT III 600 V, Impurity level 2
DC Voltage
Range Resolution Accuracy
400 mV 0.1 mV ±(1.0% + 5)
4 V 0.001 V
±(1.2% + 52)
40 V 0.01 V
400 V 0.1 V
600 V 1 V
Overload protection: 600 V; Impedance approx. 10 MOhm
AC Voltage
Range Resolution Accuracy 50-60 Hz Accuracy 400 Hz
400 mV 0.1 mV
±(1.2% + 10) ±(2.5% + 10)
4 V 0.001 V
40 V 0.01 V
±(1.0% + 10) ±(1.2% + 10)400 V 0.1 V
600 V 1 V
Frequency range 50 – 400 Hz; effective average at sinusoidal voltage; overload protection 600
V; Impedance approx. 10 MOhm
DC Current
Range Resolution Accuracy
400 µA 0.1 µA
±(1.5% + 5)
4000 µA 1 µA
40 mA 0.01 mA
400 mA 0.1 mA
Overload protection: 600 V, fuse FF500 mA
AC Current
Range Resolution Accuracy
400 µA 0.1 µA
±(1.5% + 5)
4000 µA 1 µA
40 mA 0.01 mA
400 mA 0.1 mA
Overload protection: 600 V, fuse FF500 mA; frequency range 50-400 Hz