17. TECHNICAL DATA
PPS 11810 PPS 11360 PPS 11603
Operating voltage: 100 – 240 V/AC, 50/60 Hz
Max. input current (230 V/AC, 100 V/AC): 1.2 A / 2.4 A 1.2 A / 2.5 A 1.0 A / 2.0 A
Maximum output power: 180 W 180 W 150 W
Output voltage: 1 – 18 V/DC 1 – 36 V/DC 1 – 60 V/DC
Output current: 0 – 10 A 0 – 5 A 0 – 2500 mA
Residual ripple at nominal load: 5 mV, 30 mA
Voltage control response at 10 – 100 %
load change:
50 mV
Voltage control response at mains
uctuation (90 – 260 V/AC):
20 mV
Current control response at 10 – 90 % load
change:
100 mA
Current control response at mains
uctuation (90 – 260 V/AC):
50 mA
Display accuracy: ±0.2% +3 dgt
OVP switch-off level of the V output:
+2 V (1 – 5 V)
+3 V (5 – 18 V)
+2 V (1 – 5 V)
+3 V (5 – 20 V)
+4 V (20 – 36 V)
+2 V (1 – 5 V)
+3 V (5 – 20 V)
+4 V (20 – 60 V)
Degree of effectiveness: 84.7 % 85.9 % 86 %
Clock signal: 100 – 120 kHz
Performance factor with active PFC: >0.95
Device fan: Temperature controlled (0 – 100 %)
Mains fuse slow-blow (5 x 20 mm): F6AL250V
Operating temperature: 0 to +45 ºC
Operating humitiy: 10 – 80 %, non-condensing
Storage temperature: -15 to +70 ºC
Storage humidity: 0 – 85 %, non-condensing
Operating altitude: max. 2000 m above mean sea level
Safety class: 2
Weight: 2.4 kg
Dimensions (W x H x D): 200 x 90 x 208 mm