Instructions

60
Connected consumer devices do
not work.
Is the voltage set correctly?
Is the polarity correct?
Check the technical data of the consumers.
The “REAR CONTROL” display
is lit. The device can not be
operated via the rotary controls.
Remote control operation is active. Put the rear “MODE” slider
into the “Normal” position.
The “O P PFF” display is lit. The DC output was switched off through the remote control
output (10). Release the connection between contacts 4 and 5.
The output is switched on again.
The output current is limited to
5 A, although the current settings
are higher.
The output current is limited to 5 A. For higher currents,
connect the consumer to the rear main output.
The “C.C.” LED is lit. Constant current operation:
The preset current was exceeded. Check power consumption
on your consumer and increase the current limitation on your
power unit, if applicable.
The “C.V.” LED is lit. Constant voltage operation:
The power unit works normally. The output provides the
constant voltage set.
OVP Over-voltage protection:
See chapter PROTECTIVE MEASURES.
OtP Overheating protection:
See chapter PROTECTIVE MEASURES.
OLP Overload-protection:
See chapter PROTECTIVE MEASURES.
Repairs other than those described above may only be carried out by an authorised
specialist.
16. DISPOSAL
This symbol must appear on any electrical and electronic equipment placed on the EU
market. This symbol indicates that this device should not be disposed of as unsorted
municipal waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste. Spent batteries and
accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-