Datasheet
TECHNICAL DATA
Operating voltage 230 V/AC 50 Hz (D/FR/CH)
220 - 240 V/AC 50 Hz (UK)
Self power consumption switched off <1.5 W / switched on <2.0 W
Max. power/current resistive load:
3680 W / 16 A (D/FR), 3120 W / 13 A (UK), 2300 W / 10 A (CH)
inductive load:
1150 W (230 V/AC, 5 A)
Voltage measuring range 190 – 265 V / +/- 1 % of the current value
Frequency measuring range 46 - 65 Hz
Current resolution 0.001 A (16.00 A)
Power measuring range 0.23 - 3680 W
Efficiency factor measuring range 0.01 - 1.00
Performance factor resolution 0.01
GHG/CO
2
measuring range 0.001 - 39999.9 kg
GHG/CO
2
resolution 0.001 kg
Measuring time range 0 hour 0 min. - 9999 h 59 min.
Overload limit setting range 1 - 3699 W
Currency €, $, £, CHF
Rate resolution 0.001
Operating conditions +5 to +40 °C, 10 – 90 % RH (non-condensing)
Operating height: max. 2000 m (above sea level)
Storage conditions -10 to +60 °C, 10 – 90 % RH (non-condensing)
Dimensions (W x H x D) 70 x 127 x 80 mm
Weight approx. 170 g
Home plug
Standard IEEE 1901, home plug AV compatible
Connection option max. 8 energy costs meters
Media access CSMA/CA
Supported standard IPv4/MLDv2
Accuracy (at 23°C (+/- 5°C)) at harmonic distortion of <15%
Voltage +/- (1 % + 1 count)
Current +/- (1 % + 5 count)
Power +/- (1 % + 1 count)
System/device requirements
Apple iOS iPhone 4s/5/5C/5S/6/6S, iPod touch 5th generation, iPad 3/4/Air/mini
Android version 4.3 and later
PACKAGE CONTENT
Energy costs meter // Operating instructions
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2016 by Conrad Electronic SE. V2_0316_02_HK