Safety data sheet

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no. 101137
Material Safety Data Sheet
Page 2 of 6
4. First Aid Measures:
Inhalation: Remove to fresh air. Give oxygen if breathing is difficult.
Eye contact: Flush thoroughly with water for 15 minutes.
Skin contact: Wash with soap and water.
Ingestion: Dring lots of water. Do not induse vomiting. Call a physician.
After first aid, get appropriate in-plant, paramedic, or community medical support.
5. Fire Fighting Measures:
Flash point: Non flammable
LEL: N/A
UEL: N/A
Flammability classification: Non flammable
Extinguishing media: Use extinguishing media appropriate for surrounding area.
Hazardous combustion products: May release fumes of phosphorus oxide if involved in fire.
Fire-fighting instructions: Do not release runoff from fire control methods to sewers or waterways.
Fire-fighting equipment: Because fire may produce toxic thermal docomposition products, wear a self-contained
breathing apparatus (SCBA) with a full facepiece operated in pressure-demand or
positive-pressure mode.
6. Accidental Release Measures:
Spill response notice:
Only persons properly qualified to respond to an emergency involving hazardous substances may respond to a spill according
to federal regulations (OSHA 29 CFR 1910.120(a)(v)) and per your company´s emergency response plan and
guidelines/procedures. See section 13, special instructions for disposal assistance.
Spill/Leak procedures:
Carefully sweep up and discard. Clean spill area with cold water. If propared buffer solution is spilled neutralize and mop area.
Small spills:
Wipe and clean area.
Containment:
For large spills, dike far agead of liquid spill for later disposal. Do not release into sewers or waterways.
Cleanup technique:
Scoop up spilled material into a large beaker and dissolve with water. Adjust to a pH between 6 and 9 with an alkali, such as
soda ash or sodium bicarbonate. Flush reacted material to the drain with a large excess of water. Decontaminate the area of
the spill with a soap solution.
Dispose of all wastes in accordance with federal, state and local regulation.
Regulatory requirements: Follow applicable OSHA regulations (29 CFR 1910.120).