Safety data sheet

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no. 101137
Material Safety Data Sheet
Page 5 of 6
10. Stability and Reactivity:
Stability:
Hydrion buffer salt is stable at room temperature in closed containers under normal storage and handling conditions.
Polymerization:
Hazardous polymerization cannot occur.
Chemical incompatibilities:
Hazardous reaction in aqueous solution may occur with chlorine, hypochlorus acid, hypochlorites, cyanides or sulfides.
11. Toxicological Information:
Toxicity data:
Eye effects: May cause eye mild irritation.
Skin effects: Mild irritant to the skin and mucous membranes.
Acute inhalation effects: Human, inhalation, not reported
Acute oral effects: Rat, oral, LD50: 3200 mg/kg, potassium bithalate
Carcinogenicity: Not reported
Mutagenicity: Not reported
Teratogenicity: Not reported.
12. Ecological Information:
No ecological data available for this product.
13. Disposal Considerations:
Special instructions (disposal):
Dilute material with excess water making a weaker than 5% solution. Adjust to a pH between 6 and 9 with an alkali, such as
soda ash or sodium bicarbonate. Open cold water tap completely, slowly pour the reacted material to the drain. Allow cold
water to run for 5 minutes to completely flush the system.
Notice (disposal):
These disposal guidelines are based on federal regulations and may be superseded by more stringent state or local
requirements. Please consult your locarl environmental regulatiors for more information.