Owner's Manual

Table Of Contents
Illumination strength
Range Resolution Accuracy
4000 lux 1 lux ±(6 % + 15)
40000 lux 10 lux ±(3�5 % + 10)
Colour temperature accuracy of 2856 K; Repetition accuracy ±2 %;
Temperature stability: ±0.1 % per °C; Light sensor: Silicium photo diode with spectral lter
Sound level
Range Resolution Accuracy
35 – 100 dB 0�1 dB ±5�5 dB
Accuracy at 94 dB and 1 kHz sinus; frequency range: 30 Hz – 10 kHz;
Assessment: Characteristic “C” (linear); Time assessment: Fast; Microphone: Condenser microphone
Diode Test
Test voltage approx� 1�5 V
Test current approx� 1 mA
Resolution: 0�001 V
Accuracy ±(10 % + 5)
Overload protection 600 V
Acoustic continuity tester <100 Ω continuous sound, test voltage approx 0.5 V, overload
protection 600 V
NCV: Detection range: 200 - 1,000 V/AC
Do not exceed the maximum permitted input values� Do not touch any circuits or parts of circuits if they
can have higher voltages than 25 V Acrms or 35 V/DC� Danger to life!
58