Owner's Manual

Table Of Contents
Direct current (DC)
Range Resolution Accuracy
400 μA 0.1 μA
±(1�2 % + 2)4000 μA 1 μA
40 mA 0�01 mA
400 mA 0�1 mA ±(1�5 % + 2)
10 A 0�01A ±(2�2 % + 5)
Other Features Overload protection: Fuses; 500 mA 660 V, 10 A 600 V;
Measuring time limit > 5 A: max� 30 s with 15 min break
Alternate current (AC)
Range Resolution Accuracy
400 μA 0.1 μA
±(1�5 % + 3)4000 μA 1 μA
40 mA 0�01 mA
400 mA 0�1 mA ±(1�8 % + 3)
10 A 0�01A ±(2�2 % + 6)
Other Features Overload protection: Fuses; 500 mA 660 V, 10 A 600 V;
Measuring time limit > 5 A: max� 30 s with 15 min break;
Frequency range 50 - 400 Hz
Resistance
Range Resolution Accuracy
400 Ω 0.1 Ω ±(1�8 % + 5)
4 kΩ 0.001 kΩ
±(1�5 % + 2)40 kΩ 0.01 kΩ
400 kΩ 0.1 kΩ
4 MΩ 0.001 MΩ ±(2�0 % + 2)
40 MΩ 0.01 MΩ ±(2�5 % + 2)
Other Features Overload protection 600 V;
Measuring voltage: approx� 0�28 V
56