Datasheet

Illumination strength
Range Resolution Accuracy
4000 lux 1 lux ±(6% + 15)
40000 lux 10 lux ±(3.5% + 10)
Colour temperature accuracy of 2856 K; repetition accuracy ± 2%;
Temperature stability: ±0.1 % per °C; light sensor: Silicium photo diode with
spectral filter
Sound level
Range Resolution Accuracy
35 - 100 dB 0.1 dB ±5.5 dB
Accuracy at 94 dB and 1 kHz sinus; frequency range: 30 Hz – 10 kHz;
Assessment: Characteristic “C” (linear); time assessment: Fast; Microphone:
Condenser microphone
Diode test
Test voltage Approx. 1.5 V
Test current Approx. 1 mA
Resolution 0.001 V
Accuracy ±(10% + 5)
Overload protection: 600 V
Acoustic continuity tester
<100 continuous sound, test voltage approx 0.5 V,
overload protection 600 V
NCV
Detection range: 200 - 1,000 V/AC
PACKAGE CONTENT
Multimeter // 1 set of measuring cables // Temperature sensor type K (sensors for light, noise and humidity are
integrated into the device) // 1 Battery (type 9 V Block) // Operating instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE. V2_0914_02-ETS-Mkde