Datasheet

TECHNICAL DATA
Symbol 4000 counts
Measuring rate Approx. 3 measuring operations/second
Measuring line length Approx. 80 cm each
Measuring impedance >10MΩ (V range)
Operating voltage 9 V block battery
Working conditions 0 - 40°C (<70%rF)
Operating altitude Max. 3,000 m
Storage temperature -10°C to +60°C (<80%rF)
Weight Approx. 335 g
Dimensions (LxWxH) 170 x 78 x 48 (mm)
Over-voltage category CAT III 600 V, Impurity level 2
Direct voltage (DC)
Range Resolution Accuracy
400 mV 0.1 mV
±(1.2% + 5)4 V 0.001 V
40 V 0.01 V
400 V 0.1 V
±(1.8% + 4)
600 V 1 V
Other Features Overload protection 600 V
Alternate voltage (AC)
Range Resolution Accuracy
400 mV 0.1 mV ±(1.8% + 20)
4 V 0.001 V
±(1.2% + 5)
40 V 0.01 V
400 V 0.1 V ±(1.8% + 4)
600 V 1 V ±(2.2% + 5)
Other Features
Frequency range 50 – 400 Hz;
Eective average value with sinus voltage;
Overload protection 600 V
400 mV area only through manual area selection!
Direct current (DC)
Range Resolution Accuracy
400 µA 0.1 µA
±(1.2% + 2)4000 µA 1 µA
4
0 mA
0.01 mA
400 mA 0.1 mA
±(1.5% + 2)
10 A 0.01 A
±(2.2% + 5)
Other features Overload protection: Fuses; 500 mA 660 V, 10 A 600 V ;
Measuring time limit > 5 A: max. 30 s with
15 min break