User manual
ThisisapublicationbyConradElectronicSE,Klaus-Conrad-Str.1,D-92240Hirschau(www.conrad.com).
Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microlming,orthecaptureinelectronicdata
processingsystemsrequirethepriorwrittenapprovalbytheeditor.Reprinting,alsoinpart,isprohibited.Thispublicationrepresentthe
technicalstatusatthetimeofprinting.
G
10mVto5V/div 1:1
100mVto50V/div 10:1
1Vto500V/div 100:1
10Vto5000V/div 1000:1
100Vto50000V/div 10000:1
200mVto100V/div 20:1
Source CH1,CH2,D0-D15,EXT
Selection Edge,Pulse,Video,Alternative
InputX-axise CH1
InputY-axis CH2
Mode Auto/Normal/Single
Inputimpedance 200kΩ
Inputvoltagerange 60VDC/AC
Samplingrate 100MHz
Bandwidth 10MHz
Compatibility TTL,LVTTL,CMOS,LVCMOS,ECL,PECL,EIA
Storagedepth 10K-64Mtotallyor10K-16Mperchannel
ConnectthepoweradaptertotheMSOatconnection“1”andtheUSBcableatconnection
“2”andtoyourcomputer.Themeasurementdevicewillbedetectedautomaticallybyyour
operatingsystem.Then,followtheon-screeninstructions.
EstablishaUSBconnectionbetweentheoscilloscopeattachmentandyourcomputer.
Startthemeasurementprogram(includedinthescopeofdelivery)onyourcomputer.
Thestartscreenofthemeasurementsoftwareappears,andtheMSOisinitialized.Ifneces-
sary,selectyourmodel.Themeasurementsoftwareisnowreadytouse.
Usingthe“AUTO”softwarebutton,allparametersontheMSOareautomaticallyadjus-
tedsothatanoptimalsignalrepresentationappearsonthescreen.
Theproductismaintenance-free.
Inordertoensuretheaccuracyofthemeasurementdeviceoveralongperiod,itisrecom-
mendedtohavethedevicecalibratedonceayear.
Nevercleantheproductwhenitisturnedon.Useaclean,dry,softclothforcleaning.Donot
useaggressivecleaningagents,asthesecancausediscolouration.Donotpresstoostrongly
onthesurfacewhencleaning,topreventscratchmarks.
Disposeofanunserviceableproductinaccordancewiththerelevantstatutory
regulations.
Measurementinputs.............................2analoguechannels,16-channellogicanalyzer
Bandwidth.............................................70MHz
Inputimpedance...................................1MOhm
Inputresistance...................................25pF
Inputcoupling.......................................AC/DC/GND
Verticaldisplacement............................10mV/div–5V/div
Precision...............................................±3%
Risetime...............................................5ns
Verticalresolution.................................8Bit
Verticalstoragedepth...........................10k–16MjeKanal
Max.inputvoltage................................40V/DCor40Vp/AC
Testprobes...........................................2x(je1:1/10:1)
Samplingrate.......................................200MS/s
Timebasis............................................5ns/div–1000s/div(1-2-5sequences)
Precisionoftimebasis..........................±50ppm
Autoset.................................................Yes
Powersupply........................................8–36Vviamainsadapter(100-240V/AC)
Powerconsumption..............................Max.1A
Interface................................................USB2.0
Cablelengthformainsadapter............110cm
Cablelengthfortestprobes.................106cm
Weight..................................................1kg
Dimensions...........................................255x190x45mm(LxWxH)
Voltagemeasurement Vpp,Vamp,Vmax,Vmin,Vtop,Vmid,Vbase,Vavg,
Vrms,Vcrms,Preshoot,Overshoot
Timemeasurement Frequency,periods,risetime,falltime,positive
width,negativewidth,switched-ontime
Cursormeasurement Horizontal,vertical,Track,AUTOmeasurement
Wellenform +,-,X,/,FFT,Invert