Datasheet

AC current
Range Accuracy Resolution
400 µA
±(1.6 % reading +5 digits)
0.1 µA
4000 µA 1 µA
40 mA
±(2.0 % reading +8 digits)
10 µA
400 mA 0.1 mA
4000 A
±(2.6 % reading +4 digits)
1 mA
10 A 10. mA
Overload protection:
mAµA range: F1 fuse 6 x 32 mm F 0.5 A H 600 V (CE) Item no.: 702632
10A range: F2 fuse 6 x 25 mm F 10 A H 600 V (CE) Item no.: 700161
Measuring operations of >5 A may only be performed for at most 10 seconds with a subsequent measuring
pause of 15 minutes
Frequency response: 45 – 400 Hz
Display: Sine wave valid value (average value response)
Resistance
Range Accuracy Resolution
400 Ω ±(1.6 % reading +3 digits) 0.1 Ω
4000 Ω
±(1.3 % reading +3 digits)
1 Ω
40 kΩ 10 Ω
400 kΩ 100 Ω
4 MΩ ±(1.5 % reading +10 digits) 1 kΩ
40 MΩ ±(2.0 % reading +8 digits) 10 kΩ
Overload protection: 600 V
Diode / continuity text
Acoustic continuity tester: 10 Ω permanent sound
Acoustic continuity tester resolution: 0.1 Ω
Diode test voltage: 1.5 V
Overload protection: 600 V
Non-contact voltage test
Target voltage: 230 V/AC
Capacitance
Range Accuracy Resolution
40 nF Under REL status:
±(4 % reading +10 digits)
10 pF
400 nF Under REL status:
±(4 % reading +3 digits)
100 pF
4 µF 1 nF
40 µF ±(4 % reading +3 digits) 100 Ω
100 µF ± (5 % reading +10 digits) 100 nF
Overload protection: 600 V