Technical Data
HPS-11530 HPS-11560 HPS-13015 HPS-13030 HPS-16010
Output power 450 W 900 W 450 W 900 W 600 W
Output voltage 1 - 15 V/DC 1 - 15 V/DC 1 - 30 V/DC 1 - 30 V/DC 1 - 60 V/DC
Output current 0 - 30 A 0 - 60 A 0 - 15 A 0 - 30 A 0 - 10 A
Residual ripple at 5 mV/50 mA 5 mV/100 mA 5 mV/20 mA 5 mV/40 mA 5 mV/10 mA
Nominal load (eff)
Voltage
control response at 50 mV
100% Load change
Voltage
control response at
20 mV
Mains fluctuation
(170 - 264 V/AC)
Current
control response at
150 mA 200 mA 100 mA 150 mA 100 mA
10 - 90%
Load change
Current
control response at
50 mA
Mains fluctuation
(170 - 264 V/AC)
Display accuracy +/- (0.2% + 0.3 V), +/- (0.2% + 0.3 A)
OVP switch-off level +2 V (1 - 5 V) +2 V (1 - 5 V) +2 V (1 - 5 V) +2 V (1 - 5 V) +2 V (1 - 5 V)
of the U output +3 V (5 - 15 V) +3 V (5 - 15 V) +3 V (5 - 20 V) +3 V (5 - 20 V) +3 V (5 - 20 V)
+4 V (20 - 30 V) +4 V (20 - 30 V) +4 V (20 - 60 V)
Operating voltage 220 - 240 V/AC 50/60 Hz