Instructions
46
14. Technical data
HPS-11530 HPS-11560 HPS-13015 HPS-13030 HPS-16010
Output power 450 W 900 W 450 W 900 W 600 W
Output voltage 1 - 15 V/DC 1 - 15 V/DC 1 - 30 V/DC 1 - 30 V/DC 1 - 60 V/DC
Output current 0 - 30 A 0 - 60 A 0 - 15 A 0 - 30 A 0 - 10 A
Residual ripple at
Nominal load (eff)
5 mV/50 mA 5 mV/100 mA 5 mV/20 mA 5 mV/40 mA 5 mV/10 mA
Voltage control
response at 100%
Load change
50 mV
Voltage control
response at Mains
uctuation
(170 - 264 V/AC)
20 mV
Current control re-
sponse at 10 - 90%
Load change
150 mA 200 mA 100 mA 150 mA 100 mA
Current control
response at Mains
uctuation
(170 - 264 V/AC)
50 mA
Display accuracy
+/- (0.2% + 0.3 V), +/- (0.2% + 0.3 A)
OVP switch-off level
of the U output
+2 V (1 - 5 V)
+3 V (5 - 15 V)
+2 V (1 - 5 V)
+3 V (5 - 15 V)
+2 V (1 - 5 V)
+3 V (5 - 20 V)
+4 V (20 - 30 V)
+2 V (1 - 5 V)
+3 V (5 - 20 V)
+4 V (20 - 30 V)
+2 V (1 - 5 V)
+3 V (5 - 20 V)
+4 V (20 - 60 V)
Operating voltage 220 - 240 V/AC, 50/60 Hz
Power input (max.) 2.4 A 4.7 A 2.4 A 4.5 A 3.1 A
Degree of effective-
ness
85% 85% 86% 86% 89%
Clock signal 65 - 85 kHz 65 - 85 kHz 75 - 95 kHz 75 - 95 kHz 65 - 85 kHz
Performance factor
with active PFC
>0.95
Device fan Temperature controlled (0 - 100%)
Mains fuse
(5 x 20 mm)
T3,15AL250V
Glass tube
F8AL250V
Glass tube
T3,15AL250V
Glass tube
F8AL250V
Glass tube
T4AL250V
Glass tube
Operating tempera-
ture
0 to +40 °C