User manual

Technical data, sensitivity
Input "A"
Frequency range : 50 MHz to 2500 MHz
Resolution : 0.1 kHz (= 100 Hz, Gate Time set to
"SLOW”) to
1kHz (Gate Time set to "FAST”)
Input sensitivity : 50 MHz to 75 MHz max. ==>
< 100 mV
> 75 MHz to 2500 MHz ==> < 50 mV
Impedance : 1 Mohm parallel to < 40pF
Max. input voltage : 5 Vpp, sinusoidal
Input B
Frequency range : 10 MHz to 500 MHz
Resolution : 10 Hz (Gate Time set to "SLOW”)
to
100 Hz (Gate Time set to "FAST”)
Input sensitivity : 10 MHz to 35 MHz ==> < 120 mV
> 35 MHz to < 350 MHz ==> < 50 mV
> 350 MHz to 500 MHz ==> < 120 mV
Impedance : 50 Mohm
Max. input voltage : 5 Vpp, sinusoidal
Input C
Frequency range : 10 Hz to 10 MHz
Resolution : 1 Hz (Gate Time set to "SLOW”)
to
10 Hz (Gate Time set to "FAST”)
Input sensitivity : 10 Hz to 10 MHz fi < 50 mV
(frequency measurement)
< 50 mV (measurement of the period)
Impedance : 50 Mohm
31