User manual
PRESETTING THE TARIFF AND ALARM LIMIT FOR THE CURRENT AND
RATED POWER
Some of the parameters in the display on the top right and on the bottom can be set individually.
However, the parameters can only be set one after the other. Make sure only the appropriate parameter is
selected in the display. The setting will be completed, if no button is pushed for about 10 seconds.
The measuring instrument has options for individually setting the electricity tariffs (cost/kWh) and alarm limits
for the max. current (A) or the max. electrical power. When the set current or power values are exceeded
a signal is emitted.
Setting the electricity tariff „cost/kWh €“:
Pressthekey“▼”(2)repeatedly,until„W“appearsintheupperrightdisplay.
Pressthekey“●”(9)repeatedly,untilthedisplayshows“COST/kWh€”.
The„SET“key(8)activatesthesettingsmenu.Therstdigitashes.Ifyoupressthekeyagain,
the decimal place will change.
Withthekeys“▲”(3)and“▼”(2),thevaluecanbechanged.
Tocompletethesetting,pressthekey“●”(9)orwaitforapprox.10s.Thesettingiscompleted.
Setting the alarm limit for max. current and max. rated power:
Pressthekey“●”(9)repeatedly,untilthelowerdisplayshows“TOTALkWh“.
Pressthekey“▼”(2)repeatedly,untilthedisplayshows“OVERLOAD“.
The„SET“key(8)activatesthesettingsmenu.Thelastsetunit(WorA)ashes.
Withthekeys“▲”(3)and“▼”(2)theunitcanbechanged.
„W“correspondstotheeffectivepowerinWatt
„A“correspondstothecurrentinampere.
The„SET“key(8)conrmstheselectionandswitchestothenextdigitinput.Therstdigitashes.
If you press the key again, the decimal place will change.
Withthekeys“▲”(3)and“▼”(2),thevaluecanbechanged.
Tocompletethesetting,pressthekey“●”(9)orwaitforapprox.10s.Thesettingiscompleted.
OPERATION
If the product is overloaded, it may be damaged . The warranty/guarantee will become void in
these cases.
Do not plug together several energy cost measuring instruments.
The device is not approved for use in areas where there is a risk of explosions.
Avoidareaswithstrongmagneticelds(motorsetc.).
Avoid blows or strong vibrations, as well as the use in direct sunlight.
Plug the energy cost measuring instrument into a domestic wall socket with earth protection and 230 V AC
voltage.
Make sure that the electric device you wish to measure is switched off. Connect the mains plug of the
electrical device to the earthed socket (1).
Switchontheelectricdeviceandwaitafewsecondsuntilthemeasuringinstrumentshowstherstmeasured
data.
The following displays can be switched between using the control keys:
Display on the top left
Thekey“▲”(3)switchesthefunctionsintheupperleftdisplay.Everytimeyoupressthekey,youswitch
the display.
Mains voltage, mains frequency, power factor, mains voltage
Display on top right
Thekey“▼”(2)switchesthefunctionsfortheupperrightdisplay.Everytimeyoupressthekey,youswitch
the display.
Effective power, max. measured power, alarm limit (W or A), cost forecast (to switch between day/month/year
usethe“SET”key),currentconsumption,max.measuredcurrentconsumption,effectivepower.
TheMAXvaluescanbeclearedintherelevantdisplaybypressingthe“SET”key(8)forapprox.3s.Ashort
beepconrmsthedeletionprocess.
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microlming,orthecaptureinelectronicdataprocessing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2012 by Voltcraft® V1_1112_02
Display on the bottom
Thekey“●”(9)switchesthefunctionsofthelowerdisplay.Everytimeyoupressthekey,youswitchthe
display.
Electrical work (total power consumption), electricity tariff, total electricity costs, total operating time, electrical
work (total power consumption).
DISPOSAL
a) Product
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/rechargeable
batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal
in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd =
Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash
icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores
or wherever (rechargeable) batteries are sold.
Youthusfullyourstatutoryobligationsandcontributetotheprotectionoftheenvironment.
TECHNICAL DATA
Parameter Value Accuracy (for 23°C (+/- 5°C))
Operating voltage: 230 V/AC 50 Hz
Power consumption: <1 W
Max. power/current: 3680 W / 16 A
Measuring range for voltage (V): 190 – 276 V +/-3 %
Measuring range for current (A): 0.005 – 16.00 A +/- (3 % + 0,01 A)
Measuring range for effective
power (W):
1 – 3680 W +/- (3 % + 2 W)
Measuring range kWh: 45 – 65 Hz +/-2 Hz
Measuring range kWh: 0.00 – 9999.99 kWh +/- (5 % + 0.1 kWh)
Measuring range for power factor: 0.70 – 1.00 +/- 0.1 (for >1A, sine, 50 – 60 Hz)
Button cell batteries: 2 x LR44
Dimensions (W x H x D): 130 x 63 x 80 mm
Weight: approx. 160 g
Ambient conditions 5 - 40 °C/max. 90%RH (not condensing)
Operating altitude: max. 2000 m (above MSL)