Instructions

34
Example :TRIGger:UNDER_Am:TIME 0.000003 /*set time value 3us*/
:TRIGger:UNDER_Am:TIME? /* The query returns
3.000000e-06*/
TRIGger:UNDER_Am:ALEVel
Syntax :TRIGger:UNDER_Am:ALEVel <level>
:TRIGger:UNDER_Am:ALEVel?
Description :Set or query the trigger level upper limit in under_am
trigger
Parameter :<level> ::= trigger level upper limitunit is V
Return : The query returns the trigger level upper limit in
scientific notation.
Example :TRIGger:UNDER_Am:ALEVel 0.16 /* set the trigger level
limit 160mV*/
:TRIGger:UNDER_Am:ALEVel? /*The query returns
1.600000e-01*/
TRIGger:UNDER_Am:BLEVel
Syntax :TRIGger:UNDER_Am:BLEVel <level>
:TRIGger:UNDER_Am:BLEVel?
Description : Set or query the trigger level lower limit in under_am
trigger
Parameter :<level> ::= the trigger level lower limitunit is V
Return : The query returns the trigger level upper limit in
scientific notation.
Example :TRIGger:UNDER_Am:BLEVel 0.16 /*set the trigger level
lower limit 160mV*/
:TRIGger:UNDER_Am:BLEVel? /* The query returns
1.600000e-01*/
TRIGger:UART
The list of commands
TRIGger:UART:SOURce
TRIGger:UART:CONdition