User manual

DSO-1000D Programming Manual
78
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:FREQuency?
>1.0E+3
Selects Channel 1, and then measures the
frequency.
:MEASure:NWIDth
Description
Returns the first negative pulse width timing.
Syntax
:MEASure:NWIDth{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the negative pulse width in
seconds.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:NWIDth?
4.995E-04
Selects Channel 1, and then measures the negative
pulse width.
:MEASure:PDUTy
Description
Returns the positive duty cycle ratio as percentage.
Syntax
:MEASure:PDUTy{?}
Related
commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the positive duty ratio.
Query
Query