Instructions

41
“MEASUREMENT” options - “BASIC SETTING”
Select“MEASUREMENT”inthenavigationbarandentersettingsin“BASICSETTING”.
LOGGER ID
LoggerIDisafourdigitidentier.Enteranumberbetween0000and9999e.g.0014.
UsedifferentloggerIDstoidentifydataloggerswithe.g.differentcongurationlefor
different usage.
RECORD START
CONDITION
Select one of the following options to determine when data logger starts recording. Each
option has a default stop setting.
“IMMEDIATELYUNTILMEMORYFULL”:Dataloggerstartsrecordingdataimmediately
until the memory is full.
“STARTUPONKEYPRESS”:DataloggerstartsrecordingafterholdingbuttonENTER (7)
pressed for few seconds. Data logger stops recording until memory is full.
“STARTUPONSTARTTIME”:Dataloggerstartsrecordingatadeneddateandtime
until the memory is full.
“START/STOPTIME”:Dataloggerstartsandstopsrecordingdataatadeneddateand
time.
RECORD START
CONDITION
“CIRCULARLOGGING”:Dataloggerstartsrecordingimmediatelyandcircularly.The
newest data overwrites the oldest data. It stops recording/logging once the battery is
depletedor“CIRCULARLOGGING”hasbeenreplacedbyanother“RECORDSTART
CONDITION”duringconguration.
STOP STYLE
Select one of the following options to determine when data logger ends recording.
“NONE”:Nostopconditionisspecied.Dataloggerstopsrecordingbasedonthe
“RECORDSTARTCONDITION”setting.
“STOPBUTTON”:DataloggerstopsrecordingafterholdingbuttonENTER (7) pressed
for few seconds.
“AFTERPDFCREATED”:DataloggerstopsrecordingafterPDFreportisgenerated.
START TIME Denedateandtimewhentostartrecordingdata.
STOP TIME Denedateandtimewhentostoprecordingdata.
START DELAY
MINUTES
Denedelaytimeofimmediatestartofrecording.
SAMPLING RATE
Denehowfrequentthedataloggermeasuresandrecordsdatain“MINUTES”or
“HOURS”.
When using the data logger at extremely low temperatures, choose a longer
sampling rate to decrease power consumption and to prolong the battery life.
RECORDING TIME
This value is automatically calculated based on the sampling rate and cannot be set by
the user.