After successful programming, the recording process can be started at the intended location by •
pressing the button on the datalogger (8). The start is signaled by the simultaneous blinking of
the LEDs „REC“ and „ALM“.
Once the preset recording rate is reached (example 50), the recording is terminated •
automatically.
You can also terminate the recording at any time by reading the data out on a
computer.
READING THE DATALOGGER9.
Start the Voltsoft software and connect the data logger to the computer. Follow the instructions 1.
in the software manual (section 3).
When you have nished reading data from the data logger, disconnect it from the USB port.2.
If the datalogger remains on the USB port for a longer period of time, the battery may
discharge prematurely.
DISPOSAL10.
Product
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately from the
product.
(Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/rechargeable
batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that
disposal in the domestic waste is forbidden. The designations for the heavy metals
involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable)
batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality,
our stores or wherever (rechargeable) batteries are sold.
You thus full your statutory obligations and contribute to the protection of the environment.
TECHNICAL DATA11.
Operating voltage: 3.6 V lithium Battery 1/2AA
Max. measuring data:
10000 for temperature
10000 for air humidity
10000 for air pressure
Temperature measuring
range:
-40 to +70 °C
Temperature accuracy:
+/- 1 °C (0 - +40 °C)
+/- 2 °C (residual range)
Measuring range rel. air
humidity:
0 – 100 %RH
Accuracy rel. air humidity:
+/- 3.5 % (20 - 80 %)
+/- 5 %(residual range)
Air pressure measuring
range:
700 - 1100 hPa
Air pressure accuracy:
+/- 2.5 hPa (0 - 50 ºC)
+/- 4 hPa (residual range)
Resolution: 0.1 °C / 0.1 %RH / 0.25 hPA
Measuring interval: 1 min. - 18 hr.
Dimensions (W x H x D): 142 x 28 x 25 mm
Weight: 40 g
An optional power supply (item no. 51 83 70) can also be ordered. Using the power supply unit
requires a USB adapter (can be ordered as item no. 51 31 89).
The enclosed wall mount has a self-adhesive pad. The surface must be dry, dust and
fat-free. The adhesive pad can only develop its full adhesive force above 5°C.
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2012 by Voltcraft®