User manual
The voltage and current can be set with an external voltage source or an external, adjustable resistance (abbre-
viation “Poti“) via the installed remote control connection (10). The remote control is connected
to the rear remote control connection (10). A plug for the remote connection is enclosed for the
connection.
1. Loosen the side screws of the remote connection socket and remove the front, black contact socket with a small
turning movement.
2. Insert ve connection lines with a cable cross section of at least 0.34 mm
2
from behind through the metal
sleeves. Carefully solder these cables to the solder tails no. 1, 2, 3, 4 and 5 of the black contact sockets. Please
ensure there are no short circuits.
The digits of the soldering lugs are specied on the black insulator.
Mark the loose cable ends with the corresponding contact digits (1-5) to rule out confusion.
Place the black contact sockets in reverse order into the metal sleeves and carefully screw these together.
The pin connections read as follows:
Contact 1 Internal control voltage + 5 V/DC (<50 mA)
Contact 2 Voltage setting
Contact 3 Current setting
Contact 4 Ground potential („Ground“)
Contact 5 On/off output
Contact 6 - 8 Not allocated