User manual
Three xed voltages including the current settings can be directly selected via the preset function in the device. All
three memory locations ( 1, 2, 3) are preset by the factory.
Memory
Type
PRESET 1 PRESET 2 PRESET 3
Voltage Current Voltage Current Voltage Current
CPPS-320-42 5 V Maximum 13.8 V Maximum 20 V Maximum
CPPS-320-84 5 V Maximum 13.8 V Maximum 20 V Maximum
The data memory can be set via the software provided. Please also note the chapter “Control with PC
software“.
1. Press any selection button (8). The button lights up and the preset values are indicated in the
display (2).
2. You can change the preset voltage and current values according to your needs. The output voltage can be
changed at the setting controller (4) and the output current at the (5) setting controller.
3. Press the (8) button and then any selection button (8). To test the preset values. The
preset values are indicated in the display (2). The display switches back to normal display after approximately
2 seconds.
Read the chapter “Resetting the values set” to reset the values set to the factory settings.