The control indicator REMOTE
is lit. The device can not be
operated via the rotary controls.
Remote control operation is active.
The output current is limited to
5 A / 10 A, although the current
settings are higher.
The output current is limited to 5 A / 10 A. For higher
currents, connect the consumer to the rear main output.
The control indicator C.C. is lit. Constant current operation:
The preset current was exceeded. Check power
consumption on your consumer and increase the current
limitation on your power unit, if applicable.
The control indicator C.V. LED
is lit.
Constant voltage operation:
The power unit works normally. The output provides the
constant voltage set.
Display “OVP” Over-voltage protection: See chapter PROTECTIVE
MEASURES.
Display “OtP“ Overheating protection:
See chapter PROTECTIVE MEASURES.
Display “OLP“ Overload-protection:
See chapter “Protective measures”.
Repairs other than those described above may only be carried out by an
authorised specialist. If you have any questions concerning the handling of