22. Technical data
Supply voltage: ............................. 11 - 18V=, stabilised or 100-240V~, 50/60Hz
Current drawn: .............................. Depends on charging current and rechargeable battery
(possible for 11-18V= up to 5A)
Charging Current: ......................... 0.1A - 5.0A adjustable
Discharging Current: ..................... 0.1A - 1.0A adjustable
Accumulator types: ....................... NiCd, 1 - 15 cells
NiMH, 1 - 15 cells
LiPo/LiIon/LiFe, 1 - 6 cells
Pb, 1 - 10 cells (2V per cell, 2 - 20V
Output: ........................................... 4mm sockets
Balancer sockets (JST-XH) for 2 to 6 cells
Discharge current for balancer: ... 300mA per cell
Weight: .......................................... approx. 563g
Dimensions: .................................. approx. 135 x 145 x 42mm
Ambient temperature: ................... 0°C to +35°C
Ambient air humidity: .................... Max. 90% relative, non-condensing
Special features:
Integrated balancer for LiPo batteries with 2, 3, 4, 5 or 6 cells
Delta-U cutoff
Input voltage monitoring (for protection against total discharge)
Capacity limit configurable (prevents the connected accumulator from overload)
Charge duration configurable (prevents the connected accumulator from overload)
Max. output of the electronics for charge current 50W (select lower charge current depending
on the number of cells!)
Max. output of the electronics for discharge current 5W (select lower discharge current
depending on the number of cells!)