Operation Manual
93
22. Technical data
Supply voltage: ............................. 11 - 18V=, stabilised or 100-240V~, 50/60Hz
Current drawn: .............................. Depends on charging current and rechargeable battery
(possible for 11-18V= up to 5A)
Charging Current: ......................... 0.1A - 5.0A adjustable
Discharging Current: ..................... 0.1A - 1.0A adjustable
Accumulator types: ....................... NiCd, 1 - 15 cells
NiMH, 1 - 15 cells
LiPo/LiIon/LiFe, 1 - 6 cells
Pb, 1 - 10 cells (2V per cell, 2 - 20V
Output: ........................................... 4mm sockets
Balancer sockets (JST-XH) for 2 to 6 cells
Discharge current for balancer: ... 300mA per cell
Weight: .......................................... approx. 563g
Dimensions: .................................. approx. 135 x 145 x 42mm
Ambient temperature: ................... 0°C to +35°C
Ambient air humidity: .................... Max. 90% relative, non-condensing
Special features:
• Integrated balancer for LiPo batteries with 2, 3, 4, 5 or 6 cells
• Delta-U cutoff
• Input voltage monitoring (for protection against total discharge)
• Capacity limit configurable (prevents the connected accumulator from overload)
• Charge duration configurable (prevents the connected accumulator from overload)
• Max. output of the electronics for charge current 50W (select lower charge current depending
on the number of cells!)
• Max. output of the electronics for discharge current 5W (select lower discharge current
depending on the number of cells!)