Operation Manual

82
With the "INC" button, you access the next setting (or with the button "DEC" the previous
setting). Return to the main menu with the button "Batt Type/Stop".
Here you can set the sensitivity of the delta-U detection of NiMH accumulators (voltage
difference in the delta-U charge procedure).
An excess value may overcharge the accumulator. If the value is not high
enough, the accumulator may not be charged sufficiently.
Briefly press the button "Start/Enter". The voltage value then begins to flash.
With the buttons "INC" or "DEC", you can select the voltage value (5 to 20mV). If you select
"DEFAULT", the charger uses a voltage of 7mV.
Save the setting with the button "Start/Enter"; the voltage stops blinking.
With the "INC" button, you access the next setting (or with the button "DEC" the previous
setting). Return to the main menu with the button "Batt Type/Stop".
Here you can set the sensitivity of the delta-U detection of NiCd accumulators (voltage
difference in the delta-U charge procedure).
An excess value may overcharge the accumulator. If the value is not high
enough, the accumulator may not be charged sufficiently.
Briefly press the button "Start/Enter". The voltage value then begins to flash.
With the buttons "INC" or "DEC", you can select the voltage value (5 to 20mV). If you select
"DEFAULT", the charger uses a voltage of 12mV.
Save the setting with the button "Start/Enter"; the voltage stops blinking.
With the "INC" button, you access the next setting (or with the button "DEC" the previous
setting). Return to the main menu with the button "Batt Type/Stop".
The small 3-pole connection on the left side of the charger serves to connect a temperature
sensor (not part of the delivery, must be ordered separately).
NiMH SensitivityNiMH Sensitivity
NiMH SensitivityNiMH Sensitivity
NiMH Sensitivity
D.Peak 10mV/CellD.Peak 10mV/Cell
D.Peak 10mV/CellD.Peak 10mV/Cell
D.Peak 10mV/Cell
NiCd SensitivityNiCd Sensitivity
NiCd SensitivityNiCd Sensitivity
NiCd Sensitivity
D.Peak DefaultD.Peak Default
D.Peak DefaultD.Peak Default
D.Peak Default
USB/Temp SelectUSB/Temp Select
USB/Temp SelectUSB/Temp Select
USB/Temp Select
Temp Cut-Off 80CTemp Cut-Off 80C
Temp Cut-Off 80CTemp Cut-Off 80C
Temp Cut-Off 80C