7. Usable accumulator types
NiCd
Nominal Voltage: 1.2V/cell
Max. charge current for fast charging: 1C (or lower); with specially designed
accumulators up to 2C
Discharge current cutoff at: 0.85V/cell (or higher)
NiMH
Nominal Voltage: 1.2V/cell
Max. charge current for fast charging: 1C (or lower); with specially designed
accumulators up to 2C
Discharge current cutoff at: 1.0V/cell (or higher)
LiPo
Nominal Voltage: 3.7V/cell
Max. charge voltage: 4.2V/cell
Max. charge current for fast charging: 1C (or lower)
Discharge current cutoff at: 3.0V/cell (or higher)
LiIon
Nominal Voltage: 3.6V/cell
Max. charge voltage: 4.1V/cell
Max. charge current for fast charging: 1C (or lower)
Discharge current cutoff at: 2.5V/cell (or higher)
LiFe
Nominal Voltage: 3.3V/cell
Max. charge voltage: 3.6V/cell
Max. charge current for fast charging: 4C (or lower)