Operation Manual

67
20. Technical data
Operating voltage: ........................ 11 - 18V=, stabilised
Current consumption: ................... Depends on charge current and battery
(5A adapter recommended)
Charge current: ............................. 0.1A - 5.0A adjustable
Battery types: ................................ NiCd, 1 - 14 cells
NiMH, 1 - 14 cells
LiPo, 1 - 5 cells
Pb, 1 - 6 cells (2V per cells, 2 - 12V
Output: ........................................... 4mm sockets
Balancer sockets (JST-XH) for 2, 3, 4 or 5 cells
Discharge current for balancer: ... 200mA per cell
Weight: .......................................... approx. 280g
Dimensions: .................................. Ca. 130 x 80 x 23mm
Ambient temperature: ................... 0°C to +35°C
Ambient air humidity: .................... Max. 90% relative, non-condensing
Special characteristics:
Integrated balancer for LiPo batteries with 2, 3, 4 or 5 cells
Delta-U cut-off
Input voltage monitoring (for protection against total discharge)
Capacity limit configurable (prevents the connected battery from overload)
Charge duration configurable (prevents the connected battery from overload)
Max. Output of the electronics 50W (select lower charge current depending on the number
of cells!)