Datasheet

TECHNICAL DATA
Display LCD, 4000 counts with bargraph
Measuring rate approx. 2 measuring operations/second
Measuring line length about 80 cm each
Measuring impedance >10MΩ (V range)
Automatic power-off approx. 30 minutes
Operating voltage 9V (PP3) battery
Operating conditions 0 to 50°C (<70%RH)
Operating altitude max. 2,000 m
Storage temperature -20°C to +60°C (<80%RH)
Weight of multimeter approx. 375 g
Dimensions (L x W x H) 182 x 82 x 55 (mm)
Over-voltage category CAT IV 600 V, degree of pollution 2
Protection class IP67, dust and waterproof (with measuring sockets completely
sealed)
Direct voltage
Range Resolution Accuracy
400 mV 0.1 mV ±(0.8 % + 3)
4 V 0.001 V
±(1.5 % + 2)40 V 0.01 V
400 V 0.1 V
600 V 1 V ±(1.8 % + 2)
Overload protection: 600 V; impedance 10 MΩ
Alternating voltage
Range Resolution Accuracy
400 mV 0.1 mV ±(1.5% + 6)
4 V 0.001 V ±(1.2% + 3)
40 V 0.01 V
±(1.5% + 3)
400 V 0.1 V
600 V 1 V ±(2.0% + 4)
Frequency range 50 - 60 Hz; effective average for sinusoidal voltage; overload protection 600 VM
impedance 10 MOhm
Direct current
Range Resolution Accuracy
40 mA 0.01 mA
±(1.5 % + 3)
400 mA 0.1 mA
10 A 0.1 A ±(2.5 % + 5)
Overload protection: 600 V, fuses; test time limit >1 A: max. 30 s with 15 min pause
Alternating current
Range Resolution Accuracy
40 mA 0.01 mA
±(1.8 % + 5)
400 mA 0.1 mA
10 A 0.1 A ±(3.0 % + 7)
Overload protection: 600 V, fuses; test time limit >1 A: max. 30 s with 15 min pause; frequency
range 50 - 60 Hz