User manual

B Measuring tolerances
Indication of the measuring tolerances Cx in ± (% of the reading + number of
digits = digit error)
Type Measuring Precision Dissolution Calibration of
Operation Range (SET mode)
Capacity 20 nF ±(1.0%+5dgts) 1 pF open
with 120 Hz 200 nF ±(0.7%+5dgts) 10 pF open
test frequency 2 µF ±(0.7%+3dgts) 100 pF ---
20 µF ±(0.7%+3dgts) 1 nF ---
200 µF ±(0.7%+3dgts) 10 nF ---
2000 µF ±(1.0%+5dgts) 0.1 µF short-circuit
(short)
10 mF ±(5.0%+5dgts) 1 µF short-circuit
Capacity 2000 pF ±(1.0%+5dgts) 0.1 pF open
with 1 kHz 20 nF ±(0.7%+5dgts) 1 pF open
test frequency 200 nF ±(0.7%+5dgts) 10 pF ---
2000 nF ±(0.7%+3dgts) 100 pF ---
20 µF ±(0.7%+3dgts) 1 nF ---
200 µF ±(1.0%+3dgts) 10 nF short-circuit
2000 µF ±(5,0%+5dgts) 1 µF short-circuit
pF = pico-Farad = 10 exp. -12; nF = nano-Farad = 10 exp. -9; mF = micro-
Farad = 10 exp.-6
=========================================================
Inductivity 20 mH ±(2.0%+5dgts) 1 µH short-circuit
with 120 Hz 200 mH ±(1.0%+5dgts) 10 µH short-circuit
test frequency 2000 mH ±(0.7%+5dgts) 100 µH ---
20 H (< 0.5H) ±(0.7%+5dgts) 1 mH ---
200 H (> 0.5H) ±(0.7%+5dgts) 10 mH ---
2000 H ±(1.0%+5dgts) 100 mH open
10000 H not specified 1 H ---
Inductivity 2000 µH ±(2.0%+5dgts) 0.1 µH short
with 1 kHz 20 mH ±(1,2%+5dgts) 1 µH short
test frequency 200 mH ±(0.7%+5dgts) 10 µH ---
42