Data Sheet

TECHNICAL DATA
Power supply 9 V block battery
Response time 150 ms
Emission level 0.1 – 1.00 (adjustable)
Resolution 0.1 °C/°F
IR optics 50:1
Laser output <1 mW, laser class 2, wavelength 630 - 670 nm
Operating conditions 0 to +50 °C, 10 – 90 % RH
Storage conditions -10 to +60 °C, <80 % RH
System requirements Windows® 2000 and higher
Weight 330 g
Dimensions (W x H x D) 204 x 52 x 155 mm
IR measurement range °C Accuracy Reproducibility
-50 to +20 °C +/- 3 °C +/- 1.5 °C
+20 to +500 °C +/- 1 % +/- 1 °C
+/- 0.5 % or +/- 0.5 °C
+500 to +1000 °C +/- 1.5 %
+1000 to +1200 °C +/- 2.0 % +/- 1.0 %
IR measurement range °F Accuracy Reproducibility
-58 to +68 °F +/- 5.4 °F +/- 2.7 °F
+68 to +932 °F +/- 1 % +/- 1.8 °F
+/- 0.5 % or +/- 0.9 °F
+932 to +1832 °F +/- 1.5 %
+1832 to +2192 °F +/- 2.0 % +/- 1.0 %
Contact measurement range °C Accuracy
-50 to 0 °C +/- 2 °C
0 to +1370 °C +/- (0.5 % + 1.5 °C)
Contact measurement range °F Accuracy
-58 to +32 °F +/- 3.6 °F
+32 to +2498 °F +/- (0.5 % + 3 °F)
PACKAGE CONTENT
IR thermometer // Battery // Type-K temperature sensor (measurement range -20 to +250 °C) // Tripod // USB cable //
Software CD // Transport case // Operating instructions
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2018 by Conrad Electronic SE. 1599564_v2_0518_02_IPL_ds