User manual
79
21. Technical Data
Operating voltage ........................................ Mains voltage input: 115/230 V/AC (switchable), 50/60Hz
Direct voltage input: 11 - 18 V/DC
Ifthemainsvoltageinputisused,alwaysselectthemainsvoltageatthesiteofoperationrstwiththe
voltage selection switch above the mains socket. If the wrong mains voltage is set, the charger will be
destroyed. Loss of warranty/guarantee!
Never use both inputs at the same time. This may damage the charger. Loss of guarantee/warranty!
Charging/discharging channels ................... 2
Charge current per channel ......................... 0.1 - 12.0 A (depending on the cell number and rechargeable battery
type)
Charging output per channel ....................... 120 W (channel 1 + 2 total: 240 W)
Discharge current per channel .................... 0.1 - 5.0 A (depending on the cell number and rechargeable battery
type)
Discharge output per channel ...................... 10 W max. each (channel 1 + 2 total: 20 W)
Suitable rechargeable batteries ................... NiMH/NiCd, 1 - 15 cells
LiPo/LiIon/LiFe, 1 - 6 cells
Pb, 1 - 10 cells (rated voltage 2 - 20 V)
Discharge current for balancer .................... 500 mA per cell
Delta-U-recognition ...................................... yes (for NiMH/NiCd, adjustable 3 - 15 mV/cell)
Maintenance charge current ........................ yes (for NiMH/NiCd, adjustable 50 - 300 mA, can be switched off)
Safety timer ................................................. yes (10 - 720 minutes, can be switched off)
Rechargeable battery memory .................... 6
Fan integrated ............................................. yes
Ambient conditions ...................................... Temperature 0 °C to +40 °C; humidity 0% to 90% relative, non-
condensing
Weight ......................................................... 1.46 kg
Dimensions .................................................. 180 x 139 x 60 mm (W x D x H)