User manual
97
21. TECHNICAL DATA
Operating voltage ....................................Mains voltage input: 100 - 240 V/AC, 50/60Hz
Direct voltage input: 11 - 18 V/DC
Never use both inputs at the same time. This may damage the charger. Loss of guarantee/warranty!
Charging/discharging channels ...............1
Charge current .........................................0.1 - 8.0 A (depending on the cell number and rechargeable battery type)
Charging output ....................................... max. 80 W
Discharge current ....................................0.1 - 2.0 A (depending on the cell number and rechargeable battery type)
Discharging power ................................... max. 10 W
Suitable rechargeable batteries ............... NiMH/NiCd, 1 - 15 cells
LiPo/LiIon/LiFe/LiHv, 1 - 6 cells
Pb, 1 - 12 cells (rated voltage 2 - 24 V)
Discharging current for balancer .............400 mA per cell
Delta-U detection ..................................... NiMH/NiCd: 5 - 20 mV/cell (adjustable)
Safety timer .............................................10 - 720 minutes, can be switched off
Fan integrated .........................................yes (temperature-controlled)
Ambient conditions ..................................temperature +10 °C to +40 °C; humidity 0% to 90% relative, non-condens-
ing
Weight .....................................................687 g
Dimensions .............................................. 144 x 151 x 62 mm (W x D x H)