User manual
100
18. WARNING MESSAGES ON THE DISPLAY
Warning message on the display Description
"INT. TEMP TOO HIGH" The temperature of the charger is too high. Check
the fans if required.
"EXT. TEMP TOO HIGH" The temperature measured at the rechargeable
battery via the external sensor is too high.
"DC IN TOO LOW" The input voltage (operating voltage) for the charger
is too low (< 11.0 V).
"DC IN TOO HIGH" The input voltage (operating voltage) for the charger
is too high (> 18.0 V).
"OVER TIME LIMIT" The set time limit for charging (see chapter 15) has
been exceeded.
"OVER CAPACITY LIMIT" The set capacity limit (see chapter 15) has been
exceeded.
"REVERSE POLARITY" The rechargeable battery was connected with
reversed polarity.
"CONNECTION BREAK" The connection to the battery has been disrupted,
e.g. if the battery has been disconnected during the
charging process.
"CELL NUMBER ERROR" The set cell number is wrong.
"BALANCE CONNECTOR ERROR" The balancer connection of the rechargeable
battery has been connected incorrectly or with
reversed polarity.
"NO BATTERY" No rechargeable battery is connected or the
rechargeable battery has not been recognised (e.g.
defective/deep discharged).
"CONNECTION ERROR" The rechargeable battery has been connected in-
correctly or the charger recognises doubtful values.
"BATTERY WAS FULL" The connected rechargeable battery is fully
charged. If required, check the cell number settings.