7.8.3.2 Groups
VACM Group is used to configure the information of SNMPV3 VACM Group.
Group Name: enter the security group name.
Read View Name: enter the Read View Name that the Group belongs to. The related
SNMP messages are Get, GetNext, GetBulk.
Write View Name: enter the Write View Name that the Group belongs to. The related
SNMP message is Set.
Notify View Name: enter the Notify View Name that the Group belongs to. The
related SNMP messages are Trap, Report.
Security Model: enter the Security Model Name that the Group belongs to. Any is
suitable for v1,v2,v3. USM is SNMPv3 related.
Security level: enter the Security level Name that the Group belongs to. Only NoAuth,
AuthNopriv, AuthPriv can be chosen.
SNMPv3 VGU Table – Groups
7.8.3.3 Users
USM User is used to configure the information of SNMPV3 USM User.
User Name: User name of a specific security group
Group Name: enter the security group name
Auth Protocol: enter the Auth Protocol that SNMP User and Security Group belong.
Only NoAuth ,MD5, SHA1 can be chosen. If the NoAuth is chosen, there is no need
to enter password.