User manual

VOLKTEK NSH-5509 MANAGED 8-PORT 10/100 + 1-PORT 100-FX SWITCH
default-
priority
<0-7> Set default ingress priority to use when no
priority information available
double-tag
A
lways add a tag in the egress frames
egress-set <port-list> Set outgoing traffic port list for a port-based
VLAN
flow-control Enable interface flow control
<fallback> accept incoming
frames(nonmember forward/untag forward)
<check> accept incoming
frames(nonmember drop/untag forward)
frame-type <fallback|check|secur
e>
<secure> accept incoming
frames(nonmember drop/untag drop)
inactive Disable specified port(s) on the switch
auto-
negotiation
Enable autonegotiation of specified port(s)
isolate Isolate ports belonging to the same VLAN do
not communicate with each other
lock-mac Set Lock MAC configuration for the port(s)
mac-limit action <enable|disable> Enable/Disable MAC limit for the port(s)
quantity <1-20> Set MAC limit quantity for the port(s)
mirror Enable port mirroring in the interface
name Set a name for the port(s)
no abnormal Disable individual port detection
bandwidth-limit egress Disable egress bandwidth control
ingress Disable ingress bandwidth control
ingress-mode Clear ingress bandwidth control mode
double-tag Disable double-tag in the egress frames
egress-set Disable the outgoing traffic port list for a port-
based VLAN
flow-control Disable flow control on the interface
auto-negotiation Disable auto-negotiation of specified port(s)
inactive Enable port(s) on the switch
isolate Disable port isolate on the interface
mirror Disable port mirroring in the interface
pvid <1-4094> Set a PVID for the specified interface
(range:1~4094)
rstp-active <on|off> Set RSTP port active
rstp-edge <on|off> Set RSTP port edge
rstp-p2p <auto|on|off> Set RSTP port p2p
rstp-path- <0-65535> Set RSTP port path cost
62