VOLKTEK IRF-633 RS-232/422/485 TO 100BASE-TX DEVICE SERVER
7
3.5 DB9 Male Connector Pin Assignments
PIN
RS-232
(Full-duplex)
RS-422/485
4-wire
(Full-duplex)
RS-485
2-wire
(Half-duplex)
1 DCD
2 RX RX- **DATA B(-)
3 TX TX-
4 DTR
5 GND GND GND
6 DSR
7 RTS RX+ **DATA A(+)
8 CTS TX+
9 RI
NOTE: Bi-directional RS-485 BUS line.
3.6 Serial Connection
This Device Server / Managed Media Converter features DIP switches on the rear
panel that sets the unit to the correct type of cable configuration to support connection
with a RS-232 / 422 / 485 device.
Definition of DIP Switches
No Dip description Default
1 ON: Console / OFF: Data OFF
2 RS-232 ON
3 RS-422 / 485 (4W) OFF
4 RS-485 (2W) OFF
5 NA OFF
6 NA OFF
7 TMR (Terminator) OFF
For setting the control function of the serial port, see the table below:
DIP 1 Serial Connection
ON RS-232 Console
OFF Data Communication
NOTE:
1. If using console mode turn the DIP Switch 1 to ON position. For data
communication from the serial device keep the switch to OFF position. In case of
ON position data communication will be blocked and at OFF position console port
access.
2. For some RS-422/485 devices, which may not be designed to provide DB-9
connection, please check the pin definition to connect the devices.
3. For the first time installation, you have to use console mode to setup the IP and
TCP port configuration with RS-232 cable. Always use Cross Over cable, if using
Straight Through, you must use “Null Modem” to use Telnet option.